After use Should remove the skull pump (Body pump) to wash. Just loosen the fish tail screw with bare hands.
Rinse using water to spray around the mechanical seal-spring, as the liquid will capture around the spring.
And when left until the liquid hardens Will cause mechanical seal to burn Every cleaning after completion of use will make the pump clean. Work efficiently And help extend the service life of the pump
Always try to keep the outside of the pump clean. For the part that should not be touched or touched, the cleaning solution must be completely covered.
Caution is Do not spray water on the hot parts of the pump. Because it may cause some parts to break Due to acute cold And causing the liquid in the pump to eject
– There must be nothing in the pump.
– Use VG 46 lubricant for the parts inside the pump.
– The pump should be switched on for a short period of time, once a week or should be used to rotate the pump axis. This is to ensure that the lubricating oil has proper circulation.
– Should not operate if there is no mechanical seal And in the event that the seal leaks To change the seal
Maintenance work related to electrical equipment installation Must be done by someone
with expertise and will only be able to cut the electricity And must also comply with safety requirements